A common assumption is that the medical autoclave represents an infallible line of defense against all microbial life. While it is true that this equipment is
Safe, efficient, experienced, advanced technology, professional.
Premier ™
The Premier ™ Thoracoland Posterior Internal Fixation System combines 10 years of experience and technology from WEGO Medical to help spine surgeons safely and efficiently deal with complex spinal disorders.
It is suitable for thoracolumbar degeneration, fracture, tumor and deformity patients with mature bones to perform T2-S2 segmental orthosis, full-line plant products with optimized fixation depth, low notch and high strength.
The Premier ™ Thoracoland Posterior Internal Fixation System combines 10 years of experience and technology from WEGO Medical to help spine surgeons safely and efficiently deal with complex spinal disorders.
It is suitable for thoracolumbar degeneration, fracture, tumor and deformity patients with mature bones to perform T2-S2 segmental orthosis, full-line plant products with optimized fixation depth, low notch and high strength.
A custom-built, seamless tool for the implant provides the spine surgeon with an exceptional intraoperative experience.
Premier ™ MIS, Premier ™ CBT, Premier ™ Hollow bone cement.
Screw product line is your effective assistant and rely on to carry out minimally invasive surgery
| Code | Description | Specification | Qty |
| 23001004 | Template Rod 500mm | 50cm | 1 |
| 23002901 | Coronal Plane In-Situ Bender | Left5.5 | 1 |
| 23002902 | Coronal Plane In-Situ Bender | Right5.5 | 1 |
| 23007500 | Power Gripper | 5.5 | 1 |
| 23008900 | Pedical Screw Holder | 5.5 | 16 |
| 23009000 | Rod Sleeve | 16 | |
| 23009100 | Slippage Reduction Plate | 2 | |
| 23009200 | Socket Wrench | 2 | |
| 23009300 | Unlocking Device | 2 | |
| 23009401 | Connector 1 | long | 4 |
| 23009402 | Connector 2 | short | 4 |
| 23009500 | Drill Driver | T27 | 2 |
| 23007901 | Pre-locking Driver | Short T27 | 1 |
| 23009600 | Slippage Reduction Nut | 4 | |
| 23009701 | Tap | 4.0 | 1 |
| 23008501 | Tap | 4.5 | 1 |
| 23000009 | Instrument Case B | 1 |
| direct vertebral rotation |
| vertebral coplanar alignment(VCA) |
| Medtronic-VCM |
| Stryker-XIA3 |
| Depuy-expedium |
| K2M-MESA |


A common assumption is that the medical autoclave represents an infallible line of defense against all microbial life. While it is true that this equipment is

Sterilization is a fundamental process in any medical or laboratory environment, and selecting the right equipment ensures safety, efficiency, and reliability. A medical sterilizer is designed

Guaranteeing a safe environment for personnel is a fundamental aspect of operating any high-pressure, high-temperature equipment. An autoclave machine, while indispensable for sterilization, presents specific

Properly maintaining an autoclave machine is not just a recommendation; it’s a critical responsibility for any laboratory or medical facility. The consistent performance of this equipment